- The movable plates half overlap the fixed plates
- The movable plates are most widely separated from the fixed plates
- Both sets of plates are exactly meshed
- None of these
اس سوال کو وضاحت کے ساتھ پڑھیں
Explanation
Capacitance is maximum when the overlapping area between movable and fixed plates is greatest.
In a variable air capacitor, this occurs when the plates are fully aligned or exactly meshed.
- 5kV - 10kV
- 13kV - 30kV
- 13kV - 60kV
- None of these
اس سوال کو وضاحت کے ساتھ پڑھیں
Explanation
Modern synchronous generators typically generate voltage in the range of 13 kV to 30 kV at the generator terminals.
Step-up transformers are then used to transmit this voltage efficiently over long distances.
- C = εA²/d
- C = εA/d
- C = εA/d²
- None of these
اس سوال کو وضاحت کے ساتھ پڑھیں
Explanation
Capacitance is directly proportional to plate area (A) and dielectric permittivity (ε), and inversely proportional to plate separation (d).
This formula is fundamental for designing parallel-plate capacitors.
- Integral
- Log
- Exponential
- None of these
اس سوال کو وضاحت کے ساتھ پڑھیں
Explanation
An op-amp integrator produces an output voltage proportional to the time integral of the input signal.
It is widely used in analog computation, waveform generation, and signal processing.
- j6
- j4
- j2
- None of these
اس سوال کو وضاحت کے ساتھ پڑھیں
Explanation
If ω = 4 rad/s:
XL = j(4)(0.5)
= j2 Ω
- 15 h
- 8 h
- 10 h
- None of these
اس سوال کو وضاحت کے ساتھ پڑھیں
Explanation
Rating: 50 Ah, 10 h discharge → Rated current = 50 Ah / 10 h = 5 A
Since asked current = 5 A (matches rated),
Time = Capacity / Current = 50 Ah / 5 A = 10 h
- 1 kHz
- 20 Hz
- 100 Hz
- None of these
اس سوال کو وضاحت کے ساتھ پڑھیں
Explanation
f = cycles / time
= 100 cycles / 0.1 s
= 1000 Hz
= 1 kHz
- 8000 MW
- 800 MW
- 4000 MW
- None of these
اس سوال کو وضاحت کے ساتھ پڑھیں
Explanation
Pakistan’s first HVDC transmission line (Matiari‑Lahore ±660 kV) is designed to transmit up to 4,000 MW of power.
This high‑capacity link helps evacuate bulk generation from the south to load centers in the north efficiently.
- 127 V
- 381 V
- 220 V
- None of these
اس سوال کو وضاحت کے ساتھ پڑھیں
Explanation
V_phase = V_line / √3
= 220 / √3
≈ 127 V
- P = 1/T ∫₀ᵀ p(t) dt
- P = N/T ∫₀ᵀ p(t) dt
- P = 2N/T ∫₀ᵀ p(t) dt
- None of these
اس سوال کو وضاحت کے ساتھ پڑھیں
Explanation
Average power in an AC circuit is the mean of instantaneous power over one complete cycle.
It accounts for both voltage and current variations to give the net power delivered.