- 10 Ω
- 20 Ω
- 50 Ω
- None of these
اس سوال کو وضاحت کے ساتھ پڑھیں
Explanation
XL = 2πfL = 2π × 50 × 0.1 ≈ 31.42 Ω
XC = 1 / (2πfC) = 1 / (2π × 50 × 100 × 10^-6) ≈ 31.83 Ω
Z = √(R² + (XL - XC)²)
= √(10² + (31.42 - 31.83)²)
= √(100 + (-0.41)²)
≈ √100
≈ 10 Ω
- 5
- 20
- 50
- None of these
اس سوال کو وضاحت کے ساتھ پڑھیں
Explanation
RD = 2kΩ, ro = 50kΩ
Voltage gain Av ≈ gm × (RD || ro)
Since ro >> RD,
Av ≈ gm × RD
Assuming gm ≈ 10 mS (typical for 5 mA Id),
Av ≈ 10 × 10^-3 × 2 × 10^3 = 20
- 32540 kg
- 18960 kg
- 52630 kg
- None of these
اس سوال کو وضاحت کے ساتھ پڑھیں
Explanation
Energy output = 500 MW = 500 × 10^6 J/s
Per hour = 500 × 10^6 × 3600 J = 1.8 × 10^12 J
Efficiency = 38% = 0.38
Input energy = 1.8 × 10^12 / 0.38 = 4.7368 × 10^12 J
Coal consumption = 4.7368 × 10^12 / (25 × 10^6) ≈ 189474 kg ≈ 18960 kg
- To regulate the voltage during load variations
- To detect overcurrent in the transformer
- To detect internal faults within the transformer
- None of these
اس سوال کو وضاحت کے ساتھ پڑھیں
Explanation
A differential relay compares currents on the HV and LV sides of the transformer.
Any significant difference indicates an internal fault (like winding short-circuit).
- To preheat the feedwater using residual heat from the flue gases
- To increase the pressure of steam
- To reduce the temperature of the flue gases
- None of these
اس سوال کو وضاحت کے ساتھ پڑھیں
Explanation
The economizer recovers waste heat from flue gases to raise feedwater temperature.
This improves boiler efficiency and reduces fuel consumption.
- 1.2
- 0.4
- 0.67
- None of these
اس سوال کو وضاحت کے ساتھ پڑھیں
Explanation
Modulation index = (Vmax - Vmin) / (Vmax + Vmin)
= (10 - 2) / (10 + 2)
= 8 / 12
= 0.67
- Bode plot
- State-space representation
- Root locus method
- None of these
اس سوال کو وضاحت کے ساتھ پڑھیں
Explanation
State-space method models MIMO systems using vectors and matrices, handling multiple inputs and outputs efficiently.
It provides a comprehensive framework for time-domain analysis and modern control design.
- It provides proportional, integral, and derivative actions for better control.
- It eliminates steady-state error
- It improves system stability
- None of these
اس سوال کو وضاحت کے ساتھ پڑھیں
Explanation
PID controllers combine P, I, and D actions to reduce error, improve stability, and respond to changes effectively.
They help achieve faster, accurate, and stable system performance in closed-loop control.
- Microgrid Controllers
- Demand Side Management (DSM)
- Phasor Measurement Units (PMUs)
- None of these
اس سوال کو وضاحت کے ساتھ پڑھیں
Explanation
DSM monitors and adjusts consumer load in real time to match supply and prevent grid stress.
It helps in efficient energy usage and maintains stability in a smart grid.
- Controlled Rectifier
- Inverter
- Cycloconverter
- None of these
اس سوال کو وضاحت کے ساتھ پڑھیں
Explanation
Controlled rectifiers (like SCR-based converters) convert AC to DC with adjustable output by controlling firing angles.
They are widely used where variable DC voltage is needed from an AC supply.