BPSC PAST PAPERS MCQS
فری تیاری کیلے وٹس ایپ
گروپ جوائن کریں
Click here
Show Answers
چار آپشن میں سے کسی ایک پر کلک کرنے سے جواب سرخ ہو جائے گا۔
They are less expensive to install than AC systems.
They eliminate the need for transformers.
They reduce transmission losses and improve efficiency.
None of these
اس سوال کو وضاحت کے ساتھ پڑھیں
Explanation
HVDC systems transmit power with lower resistive losses over long distances compared to AC systems.
They also allow better control of power flow and can connect asynchronous grids efficiently .
It operates independently of the fault type.
It responds only to overcurrent conditions.
It determines fault location based on impedance measurement.
None of these
اس سوال کو وضاحت کے ساتھ پڑھیں
Explanation
Distance protection measures the impedance between the relay location and the fault to detect and isolate faults accurately.
This allows fast and selective protection of high-voltage transmission lines , even for faults far from the relay.
To act as a coolant and transfer heat to the turbine
To absorb excess neutrons and prevent overheating
To slow down fast neutrons and sustain the chain reaction
None of these
اس سوال کو وضاحت کے ساتھ پڑھیں
Explanation
Moderators (like water or graphite) reduce the speed of fast neutrons, increasing the probability of fission in fuel nuclei.
This helps maintain a sustained and controlled nuclear chain reaction in the reactor core.
The system can be controlled using a single input.
All state variables can be reconstructed from output measurements.
The system remains stable for all input conditions.
None of these
اس سوال کو وضاحت کے ساتھ پڑھیں
Explanation
Observability ensures that the internal states of an LTI system can be determined using its outputs over time.
This property is essential for designing state estimators and observers in control systems.
Manual control of power distribution
Centralized power generation
Advanced energy storage and real-time demand response
None of these
اس سوال کو وضاحت کے ساتھ پڑھیں
Explanation
Smart grids use energy storage systems and real-time monitoring to balance variable renewable generation with consumption .
This enables efficient integration of solar, wind, and other renewables while maintaining grid stability.
It does not require external power.
It lacks a rotating magnetic field.
It cannot operate at high speeds.
None of these
اس سوال کو وضاحت کے ساتھ پڑھیں
Explanation
A single-phase induction motor produces only a pulsating magnetic field , which cannot start the rotor on its own.
An auxiliary starting mechanism (like a start winding or capacitor) creates a phase shift to generate a rotating field for initial rotation.
The applied DC voltage
The presence of permanent magnets in the rotor
The interaction between the motor’s rotating magnetic field and rotor currents
None of these
اس سوال کو وضاحت کے ساتھ پڑھیں
Explanation
In a three-phase induction motor , the stator produces a rotating magnetic field that induces currents in the rotor .
The interaction between these induced rotor currents and the rotating field generates torque , causing the rotor to turn.
Lower installation cost
Higher voltage drop
Improved reliability and continuity of supply
None of these
اس سوال کو وضاحت کے ساتھ پڑھیں
Explanation
A ring main system allows electricity to flow from two directions, so if one section fails, supply can continue from the other direction .
This reduces outages and improves overall reliability compared to a radial distribution system.
All poles have positive real parts
All poles lie in the right half of the s-plane
All poles have negative real parts
None of these
اس سوال کو وضاحت کے ساتھ پڑھیں
Explanation
For a linear control system , stability requires that all poles of its characteristic equation lie in the left half of the s-plane (negative real parts) .
Poles with negative real parts ensure that system responses decay over time, preventing unbounded output.
Root locus
Routh-Hurwitz criterion
Bode plot
None of these
اس سوال کو وضاحت کے ساتھ پڑھیں
Explanation
The Routh-Hurwitz criterion determines system stability by analyzing the location of poles in the s-plane without explicitly calculating them.
It provides a systematic way to check if all poles have negative real parts, ensuring a stable control system .